mzR 2.29.5
The mzR package aims at providing a common, low-level
interface to several mass spectrometry data formats, namely mzData
(Orchard et al. 2007), mzXML
(Pedrioli et al. 2004), mzML
(Martens et al. 2010) for raw
data, and mzIdentML
(Jones et al. 2012), somewhat similar to the
Bioconductor package affyio for affymetrix raw data. No processing is
done in mzR, which is left to packages such as r BiocStyle::Biocpkg("xcms")
(Smith et al. 2006, Tautenhahn:2008) or
MSnbase (Gatto and Lilley 2012). These packages also provide more
convenient, high-level interfaces to raw and identification. data
Most importantly, access to the data should be fast and memory efficient. This is made possible by allowing on-disk random file access, i.e. retrieving specific data of interest without having to sequentially browser the full content nor loading the entire data into memory.
The actual work of reading and parsing the data files is handled by the included
C/C++ libraries or backends. The C++ reference implementation for the mzML
is the proteowizard library (Kessner et al. 2008) (pwiz in short), which in turn makes
use of the boost C++ (http://www.boost.org/) library. More recently, the
proteowizard (http://proteowizard.sourceforge.net/) (Chambers et al. 2012) has been
fully integrated using the mzRpwiz
backend for raw data, and is not the
default option. The mzRnetCDF
backend provides support to CDF
-based
formats. Finally, the mzRident
backend is available to access identification
data (mzIdentML
) through pwiz.
The mzR package is in essence a collection of wrappers to the C++ code, and benefits from the C++ interface provided through the Rcpp package (Eddelbuettel and François 2011).
IMPORTANT New developers that need to access and manipulate raw
mass spectrometry data are advised against using this infrastucture
directly. They are invited to use the corresponding MSnExp
(with on
disk mode) from theMSnbase package instead. The
latter supports reading multiple files at once and offers access to
the spectra data (m/z and intensity) as well as all the spectra
metadata using a coherent interface. The MSnbase infrastructure itself
used the low level classes in mzR, thus offering fast and efficient
access.
All the mass spectrometry file formats are organized similarly, where a set of metadata nodes about the run is followed by a list of spectra with the actual masses and intensities. In addition, each of these spectra has its own set of metadata, such as the retention time and acquisition parameters.
Access to the spectral data is done via the peaks
function. The
return value is a list of two-column mass-to-charge and intensity
matrices or a single matrix if one spectrum is queried.
Access to the chromatogram(s) is done using the chromatogram
(or
chromatograms
) function, that return one (or a list of)
data.frames. See ?chromatogram
for details. This functionality is
only available with the pwiz
backend.
The main access to identification result is done via psms
, score
and modifications
. psms
and score
will return the detailed
information on each psm and scores. modifications
will return the
details on each modification found in peptide.
Run metadata is available via several functions such as
instrumentInfo()
or runInfo()
. The individual fields can be
accessed via e.g. detector()
etc.
Spectrum metadata is available via header()
, which will return a
list (for single scans) or a dataframe with information such as the
basePeakMZ
, peaksCount
, … or, for higher-order MS the msLevel
and precursor information.
Identification metadatais available via mzidInfo()
, which will
return a list with information such as the software
,
ModificationSearched
, enzymes
, SpectraSource
and other
information for this identification result.
The availability of this metadata can not always be guaranteed, and depends on the MS software which converted the data.
mzXML
/mzML
/mzData
filesA short example sequence to read data from a mass spectrometer. First open the file.
library(mzR)
## Loading required package: Rcpp
library(msdata)
mzxml <- system.file("threonine/threonine_i2_e35_pH_tree.mzXML",
package = "msdata")
aa <- openMSfile(mzxml)
We can obtain different kind of header information.
runInfo(aa)
## $scanCount
## [1] 55
##
## $lowMz
## [1] 50.0036
##
## $highMz
## [1] 298.673
##
## $dStartTime
## [1] 0.3485
##
## $dEndTime
## [1] 390.027
##
## $msLevels
## [1] 1 2 3 4
##
## $startTimeStamp
## [1] NA
instrumentInfo(aa)
## $manufacturer
## [1] "Thermo Scientific"
##
## $model
## [1] "LTQ Orbitrap"
##
## $ionisation
## [1] "electrospray ionization"
##
## $analyzer
## [1] "fourier transform ion cyclotron resonance mass spectrometer"
##
## $detector
## [1] "unknown"
##
## $software
## [1] "Xcalibur software 2.2 SP1"
##
## $sample
## [1] ""
##
## $source
## [1] ""
header(aa,1)
## seqNum acquisitionNum msLevel polarity peaksCount totIonCurrent retentionTime
## 1 1 1 1 1 684 341427000 0.3485
## basePeakMZ basePeakIntensity collisionEnergy ionisationEnergy lowMZ highMZ
## 1 120.066 211860000 NA 0 50.3254 298.673
## precursorScanNum precursorMZ precursorCharge precursorIntensity mergedScan
## 1 NA NA NA NA NA
## mergedResultScanNum mergedResultStartScanNum mergedResultEndScanNum
## 1 NA NA NA
## injectionTime filterString spectrumId
## 1 0 <NA> controllerType=0 controllerNumber=1 scan=1
## centroided ionMobilityDriftTime isolationWindowTargetMZ
## 1 TRUE NA NA
## isolationWindowLowerOffset isolationWindowUpperOffset scanWindowLowerLimit
## 1 NA NA 50.3254
## scanWindowUpperLimit
## 1 298.673
Read a single spectrum from the file.
pl <- peaks(aa,10)
peaksCount(aa,10)
## [1] 317
head(pl)
## mz intensity
## [1,] 50.08176 6984.858
## [2,] 50.62267 7719.419
## [3,] 50.70530 7185.290
## [4,] 50.73298 7509.140
## [5,] 50.83848 9366.624
## [6,] 50.88303 8012.808
plot(pl[,1], pl[,2], type="h", lwd=1)
One should always close the file when not needed any more. This will release the memory of cached content.
close(aa)
mzIdentML
filesYou can use openIDfile
to read a mzIdentML
file (version 1.1),
which use the pwiz backend.
library(mzR)
library(msdata)
file <- system.file("mzid", "Tandem.mzid.gz", package="msdata")
x <- openIDfile(file)
mzidInfo
function will return general information about this
identification result.
mzidInfo(x)
## $FileProvider
## [1] "researcher"
##
## $CreationDate
## [1] "2012-07-25T14:03:16"
##
## $software
## [1] "xtandem x! tandem CYCLONE (2010.06.01.5) "
## [2] "ProteoWizard MzIdentML 3.0.21263 ProteoWizard"
##
## $ModificationSearched
## [1] "Oxidation" "Carbamidomethyl"
##
## $FragmentTolerance
## [1] "0.8 dalton"
##
## $ParentTolerance
## [1] "1.5 dalton"
##
## $enzymes
## $enzymes$name
## [1] "Trypsin"
##
## $enzymes$nTermGain
## [1] "H"
##
## $enzymes$cTermGain
## [1] "OH"
##
## $enzymes$minDistance
## [1] "0"
##
## $enzymes$missedCleavages
## [1] "1"
##
##
## $SpectraSource
## [1] "D:/TestSpace/NeoTestMarch2011/55merge.mgf"
psms
will return the detailed information on each
peptide-spectrum-match, include spectrumID
, chargeState
,
sequence
. modNum
and others.
p <- psms(x)
colnames(p)
## [1] "spectrumID" "chargeState"
## [3] "rank" "passThreshold"
## [5] "experimentalMassToCharge" "calculatedMassToCharge"
## [7] "sequence" "peptideRef"
## [9] "modNum" "isDecoy"
## [11] "post" "pre"
## [13] "start" "end"
## [15] "DatabaseAccess" "DBseqLength"
## [17] "DatabaseSeq" "DatabaseDescription"
## [19] "spectrum.title" "acquisitionNum"
The modifications information can be accessed using modifications
,
which will return the spectrumID
, sequence
, name
, mass
and
location
.
m <- modifications(x)
head(m)
## spectrumID sequence
## 1 index=12 LCYIALDFDEEMKAAEDSSDIEK
## 2 index=12 LCYIALDFDEEMKAAEDSSDIEK
## 3 index=285 KDLYGNVVLSGGTTMYEGIGER
## 4 index=83 KDLYGNVVLSGGTTMYEGIGER
## 5 index=21 VIDENFGLVEGLMTTVHAATGTQK
## 6 index=198 GVGGAIVLVLYDEMK
## peptideRef name mass
## 1 LCYIALDFDEEMKAAEDSSDIEK_15.9949@M$12;_57.0215@C$2;_ Carbamidomethyl 57.0215
## 2 LCYIALDFDEEMKAAEDSSDIEK_15.9949@M$12;_57.0215@C$2;_ Oxidation 15.9949
## 3 KDLYGNVVLSGGTTMYEGIGER_15.9949@M$15;__ Oxidation 15.9949
## 4 KDLYGNVVLSGGTTMYEGIGER_15.9949@M$15;__ Oxidation 15.9949
## 5 VIDENFGLVEGLMTTVHAATGTQK_15.9949@M$13;__ Oxidation 15.9949
## 6 GVGGAIVLVLYDEMK_15.9949@M$14;__ Oxidation 15.9949
## location
## 1 2
## 2 12
## 3 15
## 4 15
## 5 13
## 6 14
Since different software will use different scoring function, we
provide a score
to extract the scores for each psm. It will return a
data.frame with different columns depending on software generating
this file.
scr <- score(x)
colnames(scr)
## [1] "spectrumID" "X.Tandem.expect" "X.Tandem.hyperscore"
Other file formats provided by HUPO, such as mzQuantML
for
quantitative data (Walzer et al. 2013) are also possible in the future.
Chambers, Matthew C., Brendan Maclean, Robert Burke, Dario Amodei, Daniel L. Ruderman, Steffen Neumann, Laurent Gatto, et al. 2012. “A cross-platform toolkit for mass spectrometry and proteomics.” Nat Biotech 30 (10): 918–20. https://doi.org/10.1038/nbt.2377.
Eddelbuettel, Dirk, and Romain François. 2011. “Rcpp: Seamless R and C++ Integration.” Journal of Statistical Software 40 (8): 1–18. http://www.jstatsoft.org/v40/i08/.
Gatto, L, and K S Lilley. 2012. “MSnbase – an R/Bioconductor Package for Isobaric Tagged Mass Spectrometry Data Visualization, Processing and Quantitation.” Bioinformatics 28 (2): 288–9. https://doi.org/10.1093/bioinformatics/btr645.
Jones, A R, M Eisenacher, G Mayer, O Kohlbacher, J Siepen, S J Hubbard, J N Selley, et al. 2012. “The mzIdentML Data Standard for Mass Spectrometry-Based Proteomics Results.” Mol Cell Proteomics 11 (7): M111.014381. https://doi.org/10.1074/mcp.M111.014381.
Kessner, Darren, Matt Chambers, Robert Burke, David Agus, and Parag Mallick. 2008. “ProteoWizard: Open Source Software for Rapid Proteomics Tools Development.” Bioinformatics 24 (21): 2534–6. https://doi.org/10.1093/bioinformatics/btn323.
Martens, Lennart, Matthew Chambers, Marc Sturm, Darren Kessner, Fredrik Levander, Jim Shofstahl, Wilfred H Tang, et al. 2010. “MzML - a Community Standard for Mass Spectrometry Data.” Molecular and Cellular Proteomics : MCP. https://doi.org/10.1074/mcp.R110.000133.
Orchard, Sandra, Luisa Montechi-Palazzi, Eric W Deutsch, Pierre-Alain Binz, Andrew R Jones, Norman Paton, Angel Pizarro, David M Creasy, Jérôme Wojcik, and Henning Hermjakob. 2007. “Five Years of Progress in the Standardization of Proteomics Data 4th Annual Spring Workshop of the Hupo-Proteomics Standards Initiative April 23-25, 2007 Ecole Nationale Supérieure (Ens), Lyon, France.” Proteomics 7 (19): 3436–40. https://doi.org/10.1002/pmic.200700658.
Pedrioli, Patrick G A, Jimmy K Eng, Robert Hubley, Mathijs Vogelzang, Eric W Deutsch, Brian Raught, Brian Pratt, et al. 2004. “A Common Open Representation of Mass Spectrometry Data and Its Application to Proteomics Research.” Nat. Biotechnol. 22 (11): 1459–66. https://doi.org/10.1038/nbt1031.
Smith, C A, E J Want, G O’Maille, R Abagyan, and G Siuzdak. 2006. “XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and Identification.” Anal Chem 78 (3): 779–87. https://doi.org/10.1021/ac051437y.
Walzer, M, D Qi, G Mayer, J Uszkoreit, M Eisenacher, T Sachsenberg, F F Gonzalez-Galarza, et al. 2013. “The mzQuantML Data Standard for Mass Spectrometry-Based Quantitative Studies in Proteomics.” Mol Cell Proteomics 12 (8): 2332–40. https://doi.org/10.1074/mcp.O113.028506.